CONSTRUCTION | |
Conductor: | - Bare, annealed copper conforming to ASTM B3 and stranded in accordance with ASTM B8 (Class B) |
Insulation: | - Flame-retardant PVC insulation and nylon covering, rated 90°C per UL Standard 83 - Color Code: ICEA Method 1 |
Individual Shield: | - Isolated and individually twisted pairs or triads with an aluminum/polyester tape shield providing 100% coverage - Stranded tinned copper drain wire, two sizes smaller than insulated conductors |
Overall Shield: | - Aluminum/polyester tape shield providing 100% coverage - Stranded tinned copper drain wire, same size as insulated conductors |
Inner Jacket: | - Flame retardant PVC per UL 1569, Black - Low temp performance meets ASTM D746 brttleness temp at or below -40°C - Nylon ripcord |
Armor: | - Impervious, continuously corrugated and welded aluminum per UL 1569 & 2225 - Meets grounding requirements of NEC Article 250 |
Overall Jacket: | - Flame-retardant, moisture and sunlight resistant PVC per UL Standards 1569, black - Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C |
Applications:
- For use in Class 1 remote-control and signal circuits in accordance with NEC Article 725
- Recognized for use in Class I, II, and III, Divisions 1 and 2; or Class I, Zones 1 and 2 hazardous locations per NEC articles 501, 502, 503 and 505.
- Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays , or for direct burial
- Recognized for use on fixed or floating offshore petroleum facilities as recommended by American Petroleum Institute.
Features:
- Recognized for use in Class I, II, and III, Divisions 1 and 2; or Class I, Zones 1 and 2 hazardous locations per NEC articles 501, 502, 503 and 505.
- Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays , or for direct burial
- Recognized for use on fixed or floating offshore petroleum facilities as recommended by American Petroleum Institute.
- CCW provides EMI shielding performance
- Meets cold impact at -40°C
- Meets cold impact at -40°C
Part # | AWG Size | No. of Pair / Triad | Nom. O.D. | Lbs./M’ | ||
Core | Armor | Overall | ||||
1XL41602 | 16 | 2 pairs | .450” | .670” | .780” | 239 |
1XL41604 | 16 | 4 pairs | .560” | .800” | .910” | 342 |
1XL41608 | 16 | 8 pairs | .700” | .930” | 1.04” | 502 |
1XL41612 | 16 | 12 pairs | .850” | 1.11” | 1.22” | 687 |
1XL41624 | 16 | 24 pairs | 1.12” | 1.42” | 1.53” | 1140 |
1XL41636 | 16 | 36 pairs | 1.37” | 1.69” | 1.82” | 1618 |
1XL51604 | 16 | 4 triads | .610” | .840” | .950” | 403 |
1XL51608 | 16 | 8 triads | .820” | 1.06” | 1.17” | 650 |
1XL51612 | 16 | 12 triads | .980” | 1.24” | 1.35” | 853 |
1XL41812 | 18 | 12 pairs | .780” | 1.00” | 1.10” | 580 |
1XL41824 | 18 | 24 pairs | 1.08” | 1.39” | 1.49” | 1050 |