CONSTRUCTION | |
Conductor: | - Flexible, tinned, annealed, stranded copper |
Insulation: | - Premium Grade 90°C EP |
Separator: | - Suitable separator is applied between the conductor and insulation for easy stripping |
Jacket: | - Heavy Duty CPE; black |
Applications:
- For use up to 2000 V as power cables in wind turbine generator applications per UL Subject 6140
- Diesel electric locomotives
- Mining and earth-moving equipment
- General purpose use as flexible power leads
- Flexible power leads in cable trays in sizes 1/0 AWG and larger
- Accepted for listing as flame-resistant by MSHA
Standards:
- Diesel electric locomotives
- Mining and earth-moving equipment
- General purpose use as flexible power leads
- Flexible power leads in cable trays in sizes 1/0 AWG and larger
- Accepted for listing as flame-resistant by MSHA
- Type RHH/RHW-2 per UL 44, UL File # E90494
- c(UL)US Type RW90 per CSA C.22.2-38, UL File # E90494
- National Electrical Code (NEC)
- ICEA S-95-658/NEMA WC70
- "For CT Use" on 1/0 and larger in accordance with NEC
- Accepted for listing as flame resistant by MSHA
- RoHS Compliant
Flame test compliances:
- UL 2556 VW-1
- IEEE 1202/CSA FT4 for sizes 1/0 AWG and larger
- c(UL)US Type RW90 per CSA C.22.2-38, UL File # E90494
- National Electrical Code (NEC)
- ICEA S-95-658/NEMA WC70
- "For CT Use" on 1/0 and larger in accordance with NEC
- Accepted for listing as flame resistant by MSHA
- RoHS Compliant
Flame test compliances:
- UL 2556 VW-1
- IEEE 1202/CSA FT4 for sizes 1/0 AWG and larger
Part # | AWG Size | Stranding | Nom. Insul. Thick. | Nom. Jacket Thick | Nom. O.D. | Lbs./M’ | Allowable Ampacity | Recommended Fitting |
1B81401 | 14 | 19 | .045” | .015” | .20” | 30 | - | TB2522K |
1B81201 | 12 | 19 | .045” | .015” | .22” | 39 | - | TB2522K |
1B81001 | 10 | 27 | .045” | .015” | .25” | 56 | 55 | TB2522K |
1B80801 | 8 | 37 | .055” | .030” | .33” | 87 | 80 | TB2522K |
1B80601 | 6 | 61 | .060” | .030” | .38” | 131 | 105 | TB2522K |
1B80401 | 4 | 105 | .060” | .030” | .46” | 202 | 140 | TB2522K |
1B80201 | 2 | 158 | .060” | .030” | .51” | 285 | 190 | TB2534K |
1B80101 | 1 | 224 | .080” | .045” | .64” | 417 | 220 | TB2535K |
1B81/001 | 1/0 | 280 | .080” | .045” | .70” | 494 | 260 | TB2545K |
1B82/001 | 2/0 | 329 | .080” | .045” | .73” | 587 | 300 | TB2545K |
1B83/001 | 3/0 | 456 | .080” | .045” | .80” | 718 | 350 | TB2546K |
1B84/001 | 4/0 | 551 | .080” | .045” | .84” | 845 | 405 | TB2546K |
1B82626 | 262 | 650 | .090” | .065” | .94” | 1050 | 466 | TB2558K |
1B83131 | 313 | 777 | .090” | .065” | 1.00” | 1195 | 518 | TB2558K |
1B83737 | 373 | 925 | .090” | .065” | 1.06” | 1384 | 591 | TB2559K |
1B84444 | 444 | 1110 | .090” | .065” | 1.11” | 1634 | 652 | TB2564K |
1B85353 | 535 | 1332 | .090” | .065” | 1.20” | 1925 | 728 | TB2564K |
1B86464 | 646 | 1609 | .090” | .065” | 1.29” | 2307 | 812 | TB2574K |
1B87777 | 777 | 1924 | .090” | .065” | 1.38” | 2728 | 904 | TB2574K |
1B89292 | 929 | 2318 | .090” | .065” | 1.56” | 3570 | 1001 | TB2575K |
1B81111 | 1111 | 2745 | .115” | .095” | 1.77” | 4232 | 1119 | TB2575K |
* AMPS are based on 90°C conductor and 30°C ambient in free air.