CONSTRUCTION | |||||||||||||
Conductors: | - 18 through 10 AWG fully annealed stranded tinned copper per ASTM B-174 | ||||||||||||
Insulation: | - Premium-grade, color-coded, oil-resistant 105°C EPDM | ||||||||||||
Color Code Chart: |
|
||||||||||||
Jacket: | - Super Vu-Tron® Supreme, yellow - Temperature Range: -50°C to +105°C UL/CSA - Voltage Rating: 300 Volts Type SJOOW; 600 Volts Type SOOW |
Applications:
- Machine tools
- Power tools
- Dockside power applications
- Motor leads
- Portable machinery
- Cranes
- Submersible pumps
Features:
- Power tools
- Dockside power applications
- Motor leads
- Portable machinery
- Cranes
- Submersible pumps
- Excellent flexibility in cold temperatures
- Last longer in flex applications
- Integral Flexfill®
- Ozone- and weather-resistant
- UL Listed and CSA Certified for indoor and outdoor use
- Water-resistant
- Safety-colored
- High heat and flame resistance
- Resistant to oils, acids, and chemicals
- Excellent abrasion and cut resistance
- Sequential footage markings
Standards:
- Last longer in flex applications
- Integral Flexfill®
- Ozone- and weather-resistant
- UL Listed and CSA Certified for indoor and outdoor use
- Water-resistant
- Safety-colored
- High heat and flame resistance
- Resistant to oils, acids, and chemicals
- Excellent abrasion and cut resistance
- Sequential footage markings
- UL Flexible Cord - UL Subject 62
- CSA Flexible Cord - C22.2-49
- MSHA Approved
- RoHS Compliant
- OSHA Acceptable
- CSA Flexible Cord - C22.2-49
- MSHA Approved
- RoHS Compliant
- OSHA Acceptable
Part # | AWG Size | No. of Cond. | Cond. Strand. | Nom. Insu. Thick. | Nom. O.D. | Lbs./M’ | AMPS* | Recommended Fitting |
Type SJOOW – 300 Volt – UL/CSA | ||||||||
1BJ11802-V | 18 | 2 | 41/34 | .030” | .310” | 56 | 10 | TB2521K |
1BJ11803-V | 18 | 3 | 41/34 | .030” | .320” | 65 | 10 | TB2521K |
1BJ11804-V | 18 | 4 | 41/34 | .030” | .345” | 80 | 7 | TB2521K |
1BJ11602-V | 16 | 2 | 65/34 | .030” | .315” | 68 | 13 | TB2521K |
1BJ11603-V | 16 | 3 | 65/34 | .030” | .335” | 80 | 13 | TB2521K |
1BJ11604-V | 16 | 4 | 65/34 | .030” | .370” | 95 | 10 | TB2521K |
1BJ11402-V | 14 | 2 | 105/34 | .030” | .370” | 90 | 18 | TB2521K |
1BJ11403-V | 14 | 3 | 105/34 | .030” | .375” | 110 | 18 | TB2522K |
1BJ11404-V | 14 | 4 | 105/34 | .030” | .405” | 130 | 15 | TB2522K |
Type SOOW – 600 Volt – UL/CSA | ||||||||
1B11802-V | 18 | 2 | 41/34 | .030” | .365” | 75 | 10 | TB2521K |
1B11803-V | 18 | 3 | 41/34 | .030” | .375” | 80 | 10 | TB2521K |
1B11804-V | 18 | 4 | 41/34 | .030” | .400” | 110 | 7 | TB2522K |
1B11602-V | 16 | 2 | 65/34 | .030” | .370” | 75 | 13 | TB2521K |
1B11603-V | 16 | 3 | 65/34 | .030” | .395” | 100 | 13 | TB2522K |
1B11604-V | 16 | 4 | 65/34 | .030” | .425” | 120 | 10 | TB2522K |
1B11605-V | 16 | 5 | 65/34 | .030” | .515” | 150 | 8 | TB2523K |
1B11402-V | 14 | 2 | 105/34 | .045” | .510” | 155 | 18 | TB2523K |
1B11403-V | 14 | 3 | 105/34 | .045” | .525” | 165 | 18 | TB2523K |
1B11404-V | 14 | 4 | 105/34 | .045” | .575” | 215 | 15 | TB2534K |
1B11405-V | 14 | 5 | 105/34 | .045” | .675” | 285 | 12 | TB2535K |
1B11202-V | 12 | 2 | 168/34 | .045” | .590” | 200 | 25 | TB2534K |
1B11203-V | 12 | 3 | 168/34 | .045” | .600” | 250 | 25 | TB2534K |
1B11204-V | 12 | 4 | 168/34 | .045” | .650” | 280 | 20 | TB2535K |
1B11205-V | 12 | 5 | 168/34 | .045” | .730” | 315 | 16 | TB2535K |
1B11003-V | 10 | 3 | 259/34 | .045” | .660” | 320 | 30 | TB2535K |
1B11004-V | 10 | 4 | 259/34 | .045” | .710” | 375 | 25 | TB2535K |
1B11005-V | 10 | 5 | 259/34 | .045” | .770” | 432 | 20 | TB2536K |
*Ampacities for portable cable, continuous duty (Ambient temperature of 40°C)
May not be suitable for all installations per National Electric Code.