CONSTRUCTION | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Conductor: | - Bare,soft annealed copper per ASTM B-3 - 18 AWG (16 strand) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Insulation: | - Each conductor is concentrically insulated with a 15 mil wall of high dielectric flame retardant polymer with 5 mil wall of clear polymide (nylon) jacket extruded over primary insulation and conforming to UL requirements | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cabling: | - The applicable number of conductors are cabled together with fillers as necessary with a suitable layer - A clear mylar tape is helically applied over the core |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Color Code Chart 107: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Overall Jacket: | - Gas/vapor-tight heavy duty, flame and oil resistant neoprene (black) per UL-1277 and ICEA S-73-532 part 4 |
Applications:
- To be installed in trays, raceways, troughs, channels, ducts, conduit, and by direct burial
- Recommended for wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required
- Designed for control, power, lighting, telemetering, signal, relay traffic control, wherever flexible, small diameter cable is required such as cranes, hoists, and some robotics applications
- Cables can be flexed at -40°C
Standards:
- Recommended for wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required
- Designed for control, power, lighting, telemetering, signal, relay traffic control, wherever flexible, small diameter cable is required such as cranes, hoists, and some robotics applications
- Cables can be flexed at -40°C
- OSHA acceptable
- Recognized for use in Class 1 or 2, Division 2 hazardous locations
- UL Type power and control tray cables and Articles 318, 340, 500, and 501 of the NEC
- >Cables pass UL 1277 and IEEE 383 (70,000 BTU) flame tests
- Cables are rated as Type TC, 600 volts, 90°C
- Recognized for use in Class 1 or 2, Division 2 hazardous locations
- UL Type power and control tray cables and Articles 318, 340, 500, and 501 of the NEC
- >Cables pass UL 1277 and IEEE 383 (70,000 BTU) flame tests
- Cables are rated as Type TC, 600 volts, 90°C
Part # | AWG Size | No. of Cond. |
Nom. Jacket Thickness |
Nom. O.D. | Lbs./M’ |
1AS11802 | 18 | 2 | .045” | .275” | 46 |
1AS11803 | 18 | 3 | .045” | .290” | 50 |
1AS11804 | 18 | 4 | .045” | .315” | 60 |
1AS11805 | 18 | 5 | .045” | .335” | 71 |
1AS11806 | 18 | 6 | .045” | .365” | 83 |
1AS11807 | 18 | 7 | .045” | .380” | 106 |
1AS11808 | 18 | 8 | .045” | .420” | 109 |
1AS11809 | 18 | 9 | .045” | .450” | 120 |
1AS11810 | 18 | 10 | .045” | .455” | 126 |
1AS11811 | 18 | 11 | .045” | .470” | 135 |
1AS11812 | 18 | 12 | .045” | .470” | 142 |
1AS11813 | 18 | 13 | .045” | .490” | 153 |
1AS11814 | 18 | 14 | .045” | .490” | 165 |
1AS11815 | 18 | 15 | .045” | .515” | 170 |
1AS11816 | 18 | 16 | .045” | .515” | 175 |
1AS11817 | 18 | 17 | .060” | .590” | 230 |
1AS11818 | 18 | 18 | .060” | .590” | 230 |
1AS11819 | 18 | 19 | .060” | .590” | 240 |
1AS11821 | 18 | 21 | .060” | .605” | 270 |
1AS11824 | 18 | 24 | .060” | .660” | 285 |
1AS11825 | 18 | 25 | .060” | .680” | 300 |
1AS11830 | 18 | 30 | .060” | .700” | 335 |
1AS11837 | 18 | 37 | .060” | .775” | 386 |