CONSTRUCTION | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Conductor: | - Stranded bare copper Class B per ASTM B-3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Insulation: | - Flame-retardant cross-linked polyethylene meeting the requirements for XHHW-2 per UL 44 and the requirements of ICEA S-66-524 for XLPE insulation as standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Assembly: | - Conductors shall be cabled in concentric layers with interstices filled with suitable fillers where necessary - A binder tape (when required) of synthetic material assembles the core in a tight circular configuration |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Color Code Chart 107: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Jacket: | - Black sunlight resistant, flame retardant polyvinyl chloride per UL 1277 requirements for Type TC power and control cables |
Applications:
- Used as power and control cables in dry and wet locations
- Can be installed in cable trays, raceways, and open air
- Suitable for exposure to weather, direct burial, and for class 1 Division 2 hazardous locations as per NEC
Standards:
- Can be installed in cable trays, raceways, and open air
- Suitable for exposure to weather, direct burial, and for class 1 Division 2 hazardous locations as per NEC
- UL Type TC, 600 Volt
- UL Type XHHW-2, VW-1 Conductors
- ICEA T-29-520 (210,000 BTU/hr)
- IEEE 1202 (70,000 BTU/hr) / CSA FT4
- IEEE 383 (70,000 BTU)
- UL Subject 1277 (70,000 BTU/hr)
- OSHA Acceptable
- Meets cold bend test of -25*C per UL 1277
- UL Type XHHW-2, VW-1 Conductors
- ICEA T-29-520 (210,000 BTU/hr)
- IEEE 1202 (70,000 BTU/hr) / CSA FT4
- IEEE 383 (70,000 BTU)
- UL Subject 1277 (70,000 BTU/hr)
- OSHA Acceptable
- Meets cold bend test of -25*C per UL 1277
Part # | AWG Size | No. of Cond. | Nom. Jacket Thick. | Nom. O.D. | Lbs./M’ | Recommended Fitting |
1A51202* | 12 | 2 Flat | .045” | .270” x .430” | 86 | - |
1A51202R* | 12 | 2 | .045” | .410” | 96 | TCF05054A |
1A51203 | 12 | 3 | .045” | .435” | 125 | TCF05054A |
1A51204 | 12 | 4 | .045” | .475” | 157 | TCF05054A |
1A51205 | 12 | 5 | .045” | .520” | 191 | TCF05054A |
1A51207 | 12 | 7 | .060” | .595” | 260 | TCF05067A |
1A51209 | 12 | 9 | .060” | .695” | 340 | TCF07578A |
1A51212 | 12 | 12 | .060” | .780” | 429 | TCF10088A |
1A51219 | 12 | 19 | .080” | .955” | 681 | TCF100100A |
1A51225 | 12 | 25 | .080” | 1.10” | 885 | - |
1A51230 | 12 | 30 | .080” | 1.18” | 1029 | TCF150140A |
1A51237 | 12 | 37 | .080” | 1.27” | 1241 | TCF150140A |
*ER Rating only applies to 3 conductors or more