CONSTRUCTION | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Conductor: | - Stranded soft drawn tinned copper, Class B | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Insulation: | - Flame retardant ethylene propylene rubber meeting the requirements for EPR VW-1 per UL | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Assembly: | - Conductors shall be cabled in concentric layers with interstices filled with suitable fillers where necessary
- A binder tape (when required) of synthetic material assembles the core in a tight circular configuration |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Color Code Chart 107: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Jacket: | - Black sunlight resistant thermoplastic Chlorinated Polyethylene (CPE) |
Applications:
- Used as power and control cables in dry and wet locations
- Can be installed in cable trays, raceways, and open air
- Suitable for exposure to weather, direct burial, and for Class 1 Division 2 hazardous locations as per NEC
Standards:
- Can be installed in cable trays, raceways, and open air
- Suitable for exposure to weather, direct burial, and for Class 1 Division 2 hazardous locations as per NEC
- UL Type TC 600 Volt
- UL Type XHHW-2, VW-1 Conductors
- ICEA S-95-658 / NEMA WC70
- ICEA-T-29-520 (210,000 BTU/hr)
- IEEE 1202 (70,000 BTU/hr) / CSA FT4
- IEEE 383 (70,000 BTU/hr)
- UL Subject 1277 (70,000 BTU/hr)
- UL Type XHHW-2, VW-1 Conductors
- ICEA S-95-658 / NEMA WC70
- ICEA-T-29-520 (210,000 BTU/hr)
- IEEE 1202 (70,000 BTU/hr) / CSA FT4
- IEEE 383 (70,000 BTU/hr)
- UL Subject 1277 (70,000 BTU/hr)
Part # | AWG Size | No. of Cond. | Nom. Jacket Thick. | Nom. O.D. | Lbs./M’ | Recommended Fitting |
1AF11202F* | 12 | 2 Flat | .045” | .400” x .245” | 82 | - |
1AF11202* | 12 | 2 | .045” | .420” | 94 | TCF05040A |
1AF11203 | 12 | 3 | .045” | .435” | 124 | TCF05054A |
1AF11204 | 12 | 4 | .045” | .475” | 157 | TCF05054A |
1AF11205 | 12 | 5 | .045” | .520” | 191 | TCF05054A |
1AF11207 | 12 | 7 | .060” | .595” | 268 | TCF05067A |
1AF11209 | 12 | 9 | .060” | .695” | 347 | TCF05078A |
1AF11212 | 12 | 12 | .060” | .780” | 437 | TCF05078A |
1AF11215 | 12 | 15 | .060” | .910” | 565 | TCF100100A |
1AF11219 | 12 | 19 | .080” | .955” | 688 | TCF100100A |
1AF11225 | 12 | 25 | .080” | 1.01” | 894 | TCF125109A |
1AF11230 | 12 | 30 | .080” | 1.18” | 1040 | TCF125128A |
1AF11237 | 12 | 37 | .080” | 1.27” | 1256 | TCF125128A |
*ER Rating only applies to 3 conductors or more