FLEXIBLE AND PORTABLE CORD, Small Diameter Control
SDN - UL Type TC
90°C - 600 Volt


CONSTRUCTION
Conductor: - Bare, soft annealed copper per ASTM B-3
- 12 AWG (19 strand)
Insulation: - Each conductor is concentrically insulated with a 15 mil wall of high dielectric flame retardant polymer with 5 mil wall of clear polymide (nylon) jacket extruded over primary insulation and conforming to UL requirements
Cabling: - The applicable number of conductors are cabled together with fillers as necessary with a suitable layer
- A clear mylar tape is helically applied over the core
Color Code Chart 107:
Cond. Num. Color Cond. Num. Color
1 Black 2 Red
3 Blue 4 Orange
5 Yellow 6 Brown
7 Red w/ Black Stripe 8 Blue w/ Black Stripe
9 Orange w/ Black Stripe 10 Yellow w/ Black Stripe
11 Brown w/ Black Stripe 12 Black w/ Red Stripe
13 Blue w/ Red Stripe 14 Orange w/ Red Stripe
15 Yellow w/ Red Stripe 16 Brown w/ Red Stripe
17 Black w/ Blue Stripe 18 Red w/ Blue Stripe
19 Orange w/ Blue Stripe 20 Yellow w/ Blue Stripe
21 Brown w/ Blue Stripe 22 Black w/ Orange Stripe
23 Red w/ Orange Stripe 24 Blue w/ Orange Stripe
25 Yellow w/ Orange Stripe 26 Brown w/ Orange Stripe
27 Black w/ Yellow Stripe 28 Red w/ Yellow Stripe
29 Blue w/ Yellow Stripe 30 Orange w/ Yellow Stripe
31 Brown w/ Yellow Stripe 32 Black w/ Brown Stripe
33 Red w/ Brown Stripe 34 Blue w/ Brown Stripe
35 Orange w/ Brown Stripe 36 Yellow w/ Brown Stripe
37 Black
Overall Jacket: - Gas/vapor-tight heavy duty, flame and oil resistant neoprene (black) per UL-1277 and ICEA S-73-532 part 4
Applications:
- To be installed in trays, raceways, troughs, channels, ducts, conduit, and by direct burial
- Recommended for wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required
- Designed for control, power, lighting, telemetering, signal, relay traffic control, wherever flexible, small diameter cable is required such as cranes, hoists, and some robotics applications
- Cables can be flexed at -40°C
Standards:
- OSHA acceptable
- Recognized for use in Class 1 or 2, Division 2 hazardous locations
- UL Type power and control tray cables and Articles 318, 340, 500, and 501 of the NEC
- Cables pass UL 1277 and IEEE 383 (70,000 BTU) flame tests
- Cables are rated 600 volts, 90°C dry and 75°C wet. UL file no. E60749
Part # AWG Size No. of Cond. Nom. Jacket Thick. Nom. O.D. Lbs./M’
1AS11202 12 2 .045” .365” 109
1AS11203 12 3 .045” .385” 115
1AS11204 12 4 .045” .420” 146
1AS11205 12 5 .045” .460” 177
1AS11206 12 6 .045” .500” 209
1AS11207 12 7 .045” .570” 230
1AS11208 12 8 .060” .610” 294
1AS11209 12 9 .060” .650” 325
1AS11210 12 10 .060” .665” 350
1AS11211 12 11 .060” .685” 375
1AS11212 12 12 .060” .685” 395
1AS11213 12 13 .060” .700” 430
1AS11214 12 14 .060” .720” 455
1AS11215 12 15 .060” .755” 480
1AS11216 12 16 .060” .755” 505
1AS11217 12 17 .060” .800” 530
1AS11218 12 18 .060” .800” 555
1AS11219 12 19 .080” .800” 605
1AS11221 12 21 .080” .880” 680
1AS11224 12 24 .080” .970” 773
1AS11225 12 25 .080” .970” 782
1AS11230 12 30 .080” 1.03” 1032
1AS11237 12 37 .080” 1.15” 1120
Note: The data shown are approximate and subject to standard industry and manufacturer tolerances.