FLEXIBLE AND PORTABLE CORD, Small Diameter Control
Reel and Pendant
SDN - UL Type TC 90°C - 600 Volt


CONSTRUCTION
Conductor: - Bare,soft annealed copper per ASTM B-3
- 18 AWG (16 strand)
Insulation: - Each conductor is concentrically insulated with a 15 mil wall of high dielectric flame retardant polymer with 5 mil wall of clear polymide (nylon) jacket extruded over primary insulation and conforming to UL requirements
Cabling: - The applicable number of conductors are cabled together with fillers as necessary with a suitable layer
- A clear mylar tape is helically applied over the core
Color Code Chart 107:
Cond. Num. Color Cond. Num. Color
1 Black 2 Red
3 Blue 4 Orange
5 Yellow 6 Brown
7 Red w/ Black Stripe 8 Blue w/ Black Stripe
9 Orange w/ Black Stripe 10 Yellow w/ Black Stripe
11 Brown w/ Black Stripe 12 Black w/ Red Stripe
13 Blue w/ Red Stripe 14 Orange w/ Red Stripe
15 Yellow w/ Red Stripe 16 Brown w/ Red Stripe
17 Black w/ Blue Stripe 18 Red w/ Blue Stripe
19 Orange w/ Blue Stripe 20 Yellow w/ Blue Stripe
21 Brown w/ Blue Stripe 22 Black w/ Orange Stripe
23 Red w/ Orange Stripe 24 Blue w/ Orange Stripe
25 Yellow w/ Orange Stripe 26 Brown w/ Orange Stripe
27 Black w/ Yellow Stripe 28 Red w/ Yellow Stripe
29 Blue w/ Yellow Stripe 30 Orange w/ Yellow Stripe
31 Brown w/ Yellow Stripe 32 Black w/ Brown Stripe
33 Red w/ Brown Stripe 34 Blue w/ Brown Stripe
35 Orange w/ Brown Stripe 36 Yellow w/ Brown Stripe
37 Black
Overall Jacket: - Gas/vapor-tight heavy duty, flame and oil resistant neoprene (black) per UL-1277 and ICEA S-73-532 part 4
Applications:
- To be installed in trays, raceways, troughs, channels, ducts, conduit, and by direct burial
- Recommended for wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required
- Designed for control, power, lighting, telemetering, signal, relay traffic control, wherever flexible, small diameter cable is required such as cranes, hoists, and some robotics applications
- Cables can be flexed at -40°C
Standards:
- OSHA acceptable
- Recognized for use in Class 1 or 2, Division 2 hazardous locations
- UL Type power and control tray cables and Articles 318, 340, 500, and 501 of the NEC
- >Cables pass UL 1277 and IEEE 383 (70,000 BTU) flame tests
- Cables are rated as Type TC, 600 volts, 90°C
Part # AWG Size No. of
Cond.
Nom. Jacket
Thickness
Nom. O.D. Lbs./M’
1AS11802 18 2 .045” .275” 46
1AS11803 18 3 .045” .290” 50
1AS11804 18 4 .045” .315” 60
1AS11805 18 5 .045” .335” 71
1AS11806 18 6 .045” .365” 83
1AS11807 18 7 .045” .380” 106
1AS11808 18 8 .045” .420” 109
1AS11809 18 9 .045” .450” 120
1AS11810 18 10 .045” .455” 126
1AS11811 18 11 .045” .470” 135
1AS11812 18 12 .045” .470” 142
1AS11813 18 13 .045” .490” 153
1AS11814 18 14 .045” .490” 165
1AS11815 18 15 .045” .515” 170
1AS11816 18 16 .045” .515” 175
1AS11817 18 17 .060” .590” 230
1AS11818 18 18 .060” .590” 230
1AS11819 18 19 .060” .590” 240
1AS11821 18 21 .060” .605” 270
1AS11824 18 24 .060” .660” 285
1AS11825 18 25 .060” .680” 300
1AS11830 18 30 .060” .700” 335
1AS11837 18 37 .060” .775” 386
Note: The data shown are approximate and subject to standard industry and manufacturer tolerances.