CONSTRUCTION | |
Conductor: | - Extra flexible, stranded bare annealed copper. |
Grounding Conductor: | - Coated copper. Class B strand. Two conductors, one laid in each of the two remaining interstices. |
Extruded Stranded Shield: | - Extruded conducting stress control layer over strand. |
Insulation: | - Natural ethylene propylene rubber (EPR). |
Extruded Insulation Shield: | - Extruded conducting layer covered by an overlapped coated annealed copper tape. A color coded (black, white, and red) marker stripe is placed under the copper tape. |
Jacket: | - Yellow Chlorinated Polyethylene (CPE). |
Assembly: | - Covered grounding and ground check conductors. |
Applications:
Standards:
Features:
- For heavy duty high voltage portable power applications on mobile equipment where delivery of a heavy power load is required, such as shovels, drudges, and underground mine power distribution.
- Conforms to ICEA S-68-516 (NEMA WC8).
- Temperature ratings: Normal Continuous - 90?C, Emergency - 130?C, Short Circuit - 250?C.
- MSHA Approved.
- EPR insulation provides excellent heat, moisture, corona, chemical, and radiation resistance, flexibility for easy handling, high dielectric strength, electrical stability under stress, and low dielectric loss.
- Coated copper tape provides an effective path to ground for electrical stresses, virtually eliminates the possibility of phase to phase faults and protects against shock hazard.
- Jacket is compounded for mining service, tough and reliable, and highly resistant to tearing, punctures, abrasions, oil, and flame.
Part # | AWG Size | Stranding | Nom. Insul. Thick. | Grd. Check AWG | Grd. Cond. Strand | Nom. Jacket Thick | Nom. O.D. | Lbs./M”“ | Recommended Fitting |
5kV 100% Insulation Level (Grounded) | |||||||||
1B180603 | 6 | 7 | .090” | 8 | 7 | .110” | 1.21” | 940 | TB2564K |
1B180403 | 4 | 7 | .090” | 7 | 7 | .110” | 1.32” | 1135 | TB2564K |
1B180203 | 2 | 7 | .090” | 5 | 7 | .110” | 1.45” | 1530 | TB2574K |
1B181/003 | 1/0 | 19 | .090” | 3 | 7 | .110” | 1.63” | 2150 | TB2575K |
1B182/003 | 2/0 | 19 | .090” | 2 | 7 | .140” | 1.74” | 2660 | TB2575K |
1B184/003 | 4/0 | 19 | .090” | 1/0 | 19 | .140” | 2.00” | 3870 | TB2585K |
1B1825003 | 250 | 37 | .090” | 1/0 | 19 | .140” | 2.13” | 4495 | TB2585K |
1B1835003 | 350 | 37 | .090” | 2/0 | 19 | .140” | 2.35” | 5850 | TB2592K |
1B1850003 | 500 | 37 | .090” | 4/0 | 19 | .170” | 2.64” | 8075 | TB2593K |
8kV 100% Insulation Level (Grounded) | |||||||||
1B190603 | 6 | 7 | .115” | 10 | 7 | .110” | 1.33” | 1050 | TB2564K |
1B190403 | 4 | 7 | .115” | 8 | 7 | .110” | 1.43” | 1265 | TB2574K |
1B190203 | 2 | 7 | .115” | 6 | 7 | .110” | 1.55” | 1690 | TB2574K |
1B190103 | 1 | 19 | .115” | 5 | 7 | .110” | 1.65” | 2020 | TB2575K |
1B191/003 | 1/0 | 19 | .115” | 4 | 7 | .110” | 1.75” | 2330 | TB2575K |
1B192/003 | 2/0 | 19 | .115” | 3 | 7 | .140” | 1.88” | 2875 | TB2584K |
1B193/003 | 3/0 | 19 | .115” | 1 | 19 | .140” | 2.00” | 3325 | TB2585K |
1B194/003 | 4/0 | 19 | .115” | 1/0 | 19 | .140” | 2.12” | 4070 | TB2585K |
1B1925003 | 250 | 37 | .115” | 1/0 | 19 | .140” | 2.25” | 4810 | TB2592K |
1B1935003 | 350 | 37 | .115” | 2/0 | 19 | .140” | 2.46” | 6430 | TB2593K |
1B1950003 | 500 | 37 | .115” | 4/0 | 19 | .170” | 2.75” | 8640 | TB2595K |