TRAY CABLE, VNTC®* - PVC Jacket
PVC/Nylon Insulation
90°C - 600 Volt - UL Type TC
ER Rated


CONSTRUCTION
Conductor: - Stranded bare copper Class B per UL 83
Insulation: - Extruded polyvinyl chloride to UL requirements for Class THHN and THWN insulation, which with nylon jacket is approved for Type THHN and THWN wires per UL 83
- 14 & 12 AWG - Insulation thickness .015", Nylon thickness .004"
- 10 AWG - Insulation thickness .020", Nylon thickness .005"
Assembly: - The conductors are cabled with fillers where needed to make a round compact core and a suitable tape is applied over the construction
Color Code Chart 107:
Cond. Num. Color Cond. Num. Color
1 Black 2 Red
3 Blue 4 Orange
5 Yellow 6 Brown
7 Red w/ Black Stripe 8 Blue w/ Black Stripe
9 Orange w/ Black Stripe 10 Yellow w/ Black Stripe
11 Brown w/ Black Stripe 12 Black w/ Red Stripe
13 Blue w/ Red Stripe 14 Orange w/ Red Stripe
15 Yellow w/ Red Stripe 16 Brown w/ Red Stripe
17 Black w/ Blue Stripe 18 Red w/ Blue Stripe
19 Orange w/ Blue Stripe
Jacket: - Black sunlight resistant, flame retardant polyvinyl chloride per UL 1277 requirements for Type TC power and control cables
Applications:
- Control circuits for operation and interconnection of protective and signaling devices, and for general use in manufacturing, industrial and commercial distribution systems
- UL listed and labeled for installation in ladders, troughs, channels, solid bottom trays and other similar structures (NEC Articles 318 and 340), and in duct, conduit, wireways and all other installations approved for building wire
- In hazardous locations per NEC Articles 500 and 501. May be used in wet or dry locations, sunlight resistant, and suitable for direct burial
Standards:
- UL Type TC, 600 Volt
- NEC Type TFN Conductors
- IEEE 1202 (70,000 BTU/hr) / CSA FT4
- IEEE 383 (70,000 BTU/hr)
- UL Subject 1277 (70,000 BTU/hr)
- OSHA Acceptable
- Extended Run Rated
Part # AWG Size No. of Cond. Nom. Jacket Thick. Nom. O.D. Lbs./M’ Chart Reference Recommended Fitting
1A11002F* 10 2 .045” .280” x .430” 125 Chart 107 -
1A11002R* 10 2 .045” .420” 128 Chart 107 TCF05054A
1A11003 10 3 .045” .465” 165 Chart 107 TCF05054A
1A11004 10 4 .045” .505” 209 Chart 107 TCF05054A
1A11005 10 5 .060” .590” 268 Chart 107 TCF05067A
1A11007 10 7 .060” .640” 350 Chart 107 TCF05067A
1A11009 10 9 .060” .745” 452 Chart 107 TCF07578A
1A11012 10 12 .080” .875” 610 Chart 107 TCF10088A
1A11016 10 16 .080” .975” 817 Chart 107 TCF100100A
1A11019 10 19 .080” 1.02” 1060 Chart 107 TCF100100A
Note: The data shown are approximate and subject to standard industry and manufacturer tolerances.
*ER Rating only applies to 3 conductors or more