TRAY CABLE, VNTC®* - PVC Jacket
90°C - 600 Volt - UL Type TC
ER Rated


CONSTRUCTION
Conductor: - Stranded bare copper Class B per UL 62
Insulation: - Extruded polyvinyl chloride to UL requirements for Class TFN insulation, which with nylon jacket is approved for Type TFN wires per UL 62
Assembly: - The conductors are cables with fillers where needed to make a round compact core and a suitable tape (when required) is applied over the construction
Color Code Chart 107:
Cond. Num. Color Cond. Num. Color
1 Black 2 Red
3 Blue 4 Orange
5 Yellow 6 Brown
7 Red w/ Black Stripe 8 Blue w/ Black Stripe
9 Orange w/ Black Stripe 10 Yellow w/ Black Stripe
11 Brown w/ Black Stripe 12 Black w/ Red Stripe
13 Blue w/ Red Stripe 14 Orange w/ Red Stripe
15 Yellow w/ Red Stripe 16 Brown w/ Red Stripe
17 Black w/ Blue Stripe 18 Red w/ Blue Stripe
19 Orange w/ Blue Stripe 20 Yellow w/ Blue Stripe
21 Brown w/ Blue Stripe 22 Black w/ Orange Stripe
23 Red w/ Orange Stripe 24 Blue w/ Orange Stripe
25 Yellow w/ Orange Stripe 26 Brown w/ Orange Stripe
27 Black w/ Yellow Stripe 28 Red w/ Yellow Stripe
29 Blue w/ Yellow Stripe 30 Orange w/ Yellow Stripe
31 Brown w/ Yellow Stripe 32 Black w/ Brown Stripe
33 Red w/ Brown Stripe 34 Blue w/ Brown Stripe
35 Orange w/ Brown Stripe 36 Yellow w/ Brown Stripe
37 Black
Jacket: - Black sunlight resistant, flame retardant polyvinyl chloride per UL 1277 requirements for Type TC power and control cables
Applications:
- Control circuits for operation and interconnection of protective and signaling devices, and for general use in manufacturing, industrial and commercial distribution systems
- UL listed and labeled for installation in ladders, troughs, channels, solid bottom trays and other similar structures (NEC Articles 318 and 340), and in duct, conduit, and wireways
- In hazardous locations per NEC Articles 500 and 501. May be used in wet or dry locations, sunlight resistant, and suitable for direct burial
Standards:
- UL Type TC, 600 Volt
- NEC Type TFN Conductors
- IEEE 1202 (70,000 BTU/hr) / CSA FT4
- IEEE 383 (70,000 BTU/hr)
- UL Subject 1277 (70,000 BTU/hr)
- OSHA Acceptable
Part # AWG Size No. of
Cond.
Nom. Jacket
Thick.
Nom.
O.D.
Lbs./M’ Recommended
Fitting
1A11802F* 18 2 Flat .045” .190” x .285” 36 -
1A11802R* 18 2 .045” .270” 38 -
1A11803 18 3 .045 .285 46 TCF07540A
1A11804 18 4 .045 .310 56 TCF07540A
1A11805 18 5 .045 .335 65 TCF07540A
1A11807 18 7 .045 .360 82 TCF07540A
1A11809 18 9 .045 .420 105 TCF05054A
1A11810 18 10 .045 .450 114 TCF05054A
1A11812 18 12 .045 .460 131 TCF05054A
1A11815 18 15 .045 .510 162 TCF05054A
1A11819 18 19 .060 .570 209 TCF05067A
1A11825 18 25 .060 .655 266 TCF05067A
1A11830 18 30 .060” .695” 310 TCF07578A
1A11837 18 37 .060 .745 371 TCF07578A
Note: The data shown are approximate and subject to standard industry and manufacturer tolerances.
*ER Rating only applies to 3 conductors or more