CONSTRUCTION | |
Conductor: | - Annealed bare copper - Anapact™ Compact, Class B stranding |
Extruded Strand Shield (ESS) | - Extruded thermoset semi-conducting stress control layer over conductor |
Insulation: | - Ethylene Propylene Rubber (EPR), colored to contrast with the black conducting shield layers |
Composite Insulation Shield and Jacket: | - Six corrugated copper drain wires embedded in a extruded black conducting flame-retardant Chlorinated Polyethylene (CPE) composite insulation shield and jacket |
Applications:
- Suitable for use in wet or dry locations when installed in accordance with the NEC
- Suitable for use in aerial, direct burial, conduit, open tray, and underground duct installations
- For use in a broad range of commercial, industrial, and utility projects
Features:
- Suitable for use in aerial, direct burial, conduit, open tray, and underground duct installations
- For use in a broad range of commercial, industrial, and utility projects
- Flexibility for easy handling
- Meets Cold Bend Test at -55°C
- Reduced conductor size and shield system provides the smallest premium medium-voltage shielded, jacketed power cable with full insulation
- Smaller outside dimensions may reduce the size of duct needed or increase the ampacity per duct
- UL Listed as Type MV-105 for use in accordance with the NEC
- Sizes 1/0 AWG and larger are also listed and marked "For CT Use" in accordance with the NEC, and also meet IEEE 383 (70,000 BTU/hr
Temperature Ratings:
- Normal: 105°C
- Emergency: 140°C
- Short Circuit: 250°C
Standards:
- Meets Cold Bend Test at -55°C
- Reduced conductor size and shield system provides the smallest premium medium-voltage shielded, jacketed power cable with full insulation
- Smaller outside dimensions may reduce the size of duct needed or increase the ampacity per duct
- UL Listed as Type MV-105 for use in accordance with the NEC
- Sizes 1/0 AWG and larger are also listed and marked "For CT Use" in accordance with the NEC, and also meet IEEE 383 (70,000 BTU/hr
Temperature Ratings:
- Normal: 105°C
- Emergency: 140°C
- Short Circuit: 250°C
- ICEA S-93-639/NEMA WC74 (formerly ICEA S-68-516 NEMA WC8)
- AEIC CS8 (formerly AEIC CS6)
- AEIC CS8 (formerly AEIC CS6)
Part # | AWG | No. of Strands | Nominal Thickness | Diameter Over Ins. | Nom. O.D. | Lbs./M’ | Splices Available | Terminations Available | |
Insulation | Jacket | ||||||||
15kV – 100% Insulation Level | |||||||||
1MVU40201 | 2 | 7 | .175” | .080” | .664” | .841” | 501 | - | - |
1MVU41/001 | 1/0 | 19 | .175” | .080” | .737” | .916” | 661 | - | - |
1MVU42/001 | 2/0 | 19 | .175” | .080” | .780” | .960” | 769 | - | - |
1MVU44/001 | 4/0 | 19 | .175” | .080” | .880” | 1.07” | 1079 | - | - |
1MVU425001 | 250 | 37 | .175” | .080” | .935” | 1.13” | 1232 | - | - |
1MVU435001 | 350 | 37 | .175” | .085” | 1.03” | 1.23” | 1613 | - | - |
1MVU450001 | 500 | 37 | .175” | .085” | 1.16” | 1.36” | 2149 | - | - |
1MVU475001 | 750 | 61 | .175” | .100” | 1.34” | 1.56” | 3064 | - | - |
1MVU4100001 | 1000 | 61 | .175” | .100” | 1.50” | 1.72” | 3936 | - | - |
15kV – 133% Insulation Level | |||||||||
1MVU20201 | 2 | 7 | .220” | .080” | .755” | .937” | 574 | Cold-Heat | Cold In/Out Heat In/Out |
1MVU21/001 | 1/0 | 19 | .220” | .080” | .828” | 1.02” | 753 | - | - |
1MVU22/001 | 2/0 | 19 | .220” | .080” | .871” | 1.07” | 867 | - | - |
1MVU24/001 | 4/0 | 19 | .220” | .080” | .971” | 1.17” | 1171 | Cold-Heat | Cold In/Out Heat In/Out |
1MVU225001 | 250 | 37 | .220” | .085” | 1.03” | 1.24” | 1349 | - | - |
1MVU235001 | 350 | 37 | .220” | .085” | 1.12” | 1.33” | 1720 | - | - |
1MVU250001 | 500 | 37 | .220” | .085” | 1.25” | 1.46” | 2267 | Cold-Heat | Cold In/Out Heat In/Out |
1MVU275001 | 750 | 61 | .220” | .100” | 1.43” | 1.67” | 3216 | - | - |
1MVU2100001 | 1000 | 61 | .220” | .115” | 1.59” | 1.86” | 4164 | - | - |