CONSTRUCTION | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Conductor: | - Bare, annealed copper conforming to ASTM B-3 and stranded in accordance with ASTM B8. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Insulation: | - Cross-linked polyethylene type XHHW per UL 44. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cable Assembly: | - Insulated conductors are cabled with fillers when required - A binder tape, when required, is applied over cabled core |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Amor: | - Impervious continuously welded and corrugated aluminum sheath applied over cabled conductors | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Jacket: | - Flame-retardant, moisture and sunlight resistant black PVC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Color Code ICEA Method 1, Table E2: |
|
Applications:
- For use as services, feeders and branch circuits for power, lighting, control, and signal circuits in accordance with NEC articles 330 and 725
- Class I and II, Division 2; Class III, Divisions 1 and 2, Zone 2 hazardous locations per NEC articles 501, 502, 503, and 505.
- Installed indoors or outdoors, wet or dry locations, directly buried, embedded in concrete, in a raceway, as aerial on a messenger, or as exposed runs secured to supports in accordance with NEC article 330
Features:
- Class I and II, Division 2; Class III, Divisions 1 and 2, Zone 2 hazardous locations per NEC articles 501, 502, 503, and 505.
- Installed indoors or outdoors, wet or dry locations, directly buried, embedded in concrete, in a raceway, as aerial on a messenger, or as exposed runs secured to supports in accordance with NEC article 330
CCW armor provides an impervious barrier to moisture, gas and liquids
- CCW armor provides EMI shielding performance
- Meets cold impact at -40°C
- Factory assembled and tested cable for use as an alternate to cable in conduit wiring systems
- 90°C continuous operating temperature, wet or dry
- 130°C emergency rating
- 250°C short circuit rating
Ratings:
- CCW armor provides EMI shielding performance
- Meets cold impact at -40°C
- Factory assembled and tested cable for use as an alternate to cable in conduit wiring systems
- 90°C continuous operating temperature, wet or dry
- 130°C emergency rating
- 250°C short circuit rating
- UL 1569 metal clad cables
- UL 1309 marine shipboard cable
- IEEE 1202 flame test for use in cable tray in industrial and commercial occupancies
- ICEA T-29-520 vertical cable flame tray tests
- UL Type MC
- UL 1309 marine shipboard cable
- IEEE 1202 flame test for use in cable tray in industrial and commercial occupancies
- ICEA T-29-520 vertical cable flame tray tests
- UL Type MC
Part # | AWG Size | No. of Cond. | Nom. O.D. | Lbs./M’ | Standard Location Fittings | Hazardous Location Fittings | |
Armor | Overall | ||||||
1XA51003 | 10 | 3 | .580” | .690” | 241 | STE050 | STX050-464 |
1XA51004 | 10 | 4 | .670” | .780” | 301 | STE050 | STX050-464 |
1XA51005 | 10 | 5 | .710” | .820” | 353 | STE050 | STEX075 |
1XA51007 | 10 | 7 | .750” | .860” | 442 | STE050 | STEX075 |
1XA51009 | 10 | 9 | .890” | 1.00” | 551 | STE050 | STEX075 |
1XA51203 | 12 | 3 | .530” | .640” | 192 | ST050-462 | STX050-462 |
1XA51204 | 12 | 4 | .580” | .690” | 229 | STE050 | STX050-464 |
1XA51205 | 12 | 5 | .620” | .730” | 266 | STE050 | STX050-464 |
1XA51207 | 12 | 7 | .670” | .780” | 328 | STE050 | STX050-464 |
1XA51209 | 12 | 9 | .800” | .910” | 410 | STE050 | STEX075 |
1XA51212 | 12 | 12 | .890” | .990” | 510 | STE050 | STEX075 |
1XA51219 | 12 | 19 | 1.02” | 1.13” | 731 | STE075 | STEX100 |
1XA51237 | 12 | 37 | 1.37” | 1.48” | 1318 | STE150 | STEX150 |
1XA51403 | 14 | 3 | .490” | .600” | 155 | ST050-462 | STX050-462 |
1XA51404 | 14 | 4 | .530” | .640” | 183 | ST050-462 | STX050-462 |
1XA51405 | 14 | 5 | .580” | .690” | 213 | STE050 | STX050-464 |
1XA51407 | 14 | 7 | .620” | .730” | 257 | STE050 | STX050-464 |
1XA51409 | 14 | 9 | .710” | .820” | 312 | STE050 | STEX075 |
1XA51412 | 14 | 12 | .800” | .910” | 386 | STE050 | STEX075 |
1XA51419 | 14 | 19 | .930” | 1.04” | 544 | STE075 | STEX100 |
1XA51437 | 14 | 37 | 1.24” | 1.35” | 959 | STE100 | STEX125 |