CCW Armored Control Without Grounding Conductor, UL Type MC
600V, 90°C
Cable Tray Use, Sunlight-resistant, Direct Burial


CONSTRUCTION
Conductor: - Bare, annealed copper conforming to ASTM B-3 and stranded in accordance with ASTM B8.
Insulation: - Cross-linked polyethylene type XHHW per UL 44.
Cable Assembly: - Insulated conductors are cabled with fillers when required
- A binder tape, when required, is applied over cabled core
Amor: - Impervious continuously welded and corrugated aluminum sheath applied over cabled conductors
Jacket: - Flame-retardant, moisture and sunlight resistant black PVC
Color Code ICEA Method 1, Table E2:
Cond. Num. Color Cond. Num. Color
1 Black 2 Red
3 Blue 4 Orange
5 Yellow 6 Brown
7 Red w/ Black Stripe 8 Blue w/ Black Stripe
9 Orange w/ Black Stripe 10 Yellow w/ Black Stripe
11 Brown w/ Black Stripe 12 Black w/ Red Stripe
13 Blue w/ Red Stripe 14 Orange w/ Red Stripe
15 Yellow w/ Red Stripe 16 Brown w/ Red Stripe
17 Black w/ Blue Stripe 18 Red w/ Blue Stripe
19 Orange w/ Blue Stripe 20 Yellow w/ Blue Stripe
21 Brown w/ Blue Stripe 22 Black w/ Orange Stripe
23 Red w/ Orange Stripe 24 Blue w/ Orange Stripe
25 Yellow w/ Orange Stripe 26 Brown w/ Orange Stripe
27 Black w/ Yellow Stripe 28 Red w/ Yellow Stripe
29 Blue w/ Yellow Stripe 30 Orange w/ Yellow Stripe
31 Brown w/ Yellow Stripe 32 Black w/ Brown Stripe
33 Red w/ Brown Stripe 34 Blue w/ Brown Stripe
35 Orange w/ Brown Stripe 36 Yellow w/ Brown Stripe
Applications:
- For use as services, feeders and branch circuits for power, lighting, control, and signal circuits in accordance with NEC articles 330 and 725
- Class I and II, Division 2; Class III, Divisions 1 and 2, Zone 2 hazardous locations per NEC articles 501, 502, 503, and 505.
- Installed indoors or outdoors, wet or dry locations, directly buried, embedded in concrete, in a raceway, as aerial on a messenger, or as exposed runs secured to supports in accordance with NEC article 330
Features:
CCW armor provides an impervious barrier to moisture, gas and liquids
- CCW armor provides EMI shielding performance
- Meets cold impact at -40°C
- Factory assembled and tested cable for use as an alternate to cable in conduit wiring systems
- 90°C continuous operating temperature, wet or dry
- 130°C emergency rating
- 250°C short circuit rating
Ratings:
- UL 1569 metal clad cables
- UL 1309 marine shipboard cable
- IEEE 1202 flame test for use in cable tray in industrial and commercial occupancies
- ICEA T-29-520 vertical cable flame tray tests
- UL Type MC
Part # AWG Size No. of Cond. Nom. O.D. Lbs./M’ Standard Location Fittings Hazardous Location Fittings
Armor Overall
1XA51003 10 3 .580” .690” 241 STE050 STX050-464
1XA51004 10 4 .670” .780” 301 STE050 STX050-464
1XA51005 10 5 .710” .820” 353 STE050 STEX075
1XA51007 10 7 .750” .860” 442 STE050 STEX075
1XA51009 10 9 .890” 1.00” 551 STE050 STEX075
1XA51203 12 3 .530” .640” 192 ST050-462 STX050-462
1XA51204 12 4 .580” .690” 229 STE050 STX050-464
1XA51205 12 5 .620” .730” 266 STE050 STX050-464
1XA51207 12 7 .670” .780” 328 STE050 STX050-464
1XA51209 12 9 .800” .910” 410 STE050 STEX075
1XA51212 12 12 .890” .990” 510 STE050 STEX075
1XA51219 12 19 1.02” 1.13” 731 STE075 STEX100
1XA51237 12 37 1.37” 1.48” 1318 STE150 STEX150
1XA51403 14 3 .490” .600” 155 ST050-462 STX050-462
1XA51404 14 4 .530” .640” 183 ST050-462 STX050-462
1XA51405 14 5 .580” .690” 213 STE050 STX050-464
1XA51407 14 7 .620” .730” 257 STE050 STX050-464
1XA51409 14 9 .710” .820” 312 STE050 STEX075
1XA51412 14 12 .800” .910” 386 STE050 STEX075
1XA51419 14 19 .930” 1.04” 544 STE075 STEX100
1XA51437 14 37 1.24” 1.35” 959 STE100 STEX125
Note: The information in this specification sheet is approximate and subject to standard industry and manufacturer tolerances. Please verify specific requirements with your Omni Cable account manager.