TRAY CABLE, VNTC®* - PVC Jacket
90°C - 600 Volt - UL Type TC
ER Rated


CONSTRUCTION
Conductor: - Stranded bare copper Class B per UL 62
Insulation: - Extruded polyvinyl chloride to UL requirements for Class TFN insulation, which with nylon jacket is approved for Type TFN wires per UL 62
- Insulation Thickness: .015"
- Nylon Thickness: .004"
Assembly: - The conductors are cables with fillers where needed to make a round compact core and a suitable tape (when required) is applied over the construction
Color Code Chart 107:
Cond. Num. Color Cond. Num. Color
1 Black 2 Red
3 Blue 4 Orange
5 Yellow 6 Brown
7 Red w/ Black Stripe 8 Blue w/ Black Stripe
9 Orange w/ Black Stripe 10 Yellow w/ Black Stripe
11 Brown w/ Black Stripe 12 Black w/ Red Stripe
13 Blue w/ Red Stripe 14 Orange w/ Red Stripe
15 Yellow w/ Red Stripe 16 Brown w/ Red Stripe
17 Black w/ Blue Stripe 18 Red w/ Blue Stripe
19 Orange w/ Blue Stripe 20 Yellow w/ Blue Stripe
21 Brown w/ Blue Stripe 22 Black w/ Orange Stripe
23 Red w/ Orange Stripe 24 Blue w/ Orange Stripe
25 Yellow w/ Orange Stripe 26 Brown w/ Orange Stripe
27 Black w/ Yellow Stripe 28 Red w/ Yellow Stripe
29 Blue w/ Yellow Stripe 30 Orange w/ Yellow Stripe
31 Brown w/ Yellow Stripe 32 Black w/ Brown Stripe
33 Red w/ Brown Stripe 34 Blue w/ Brown Stripe
35 Orange w/ Brown Stripe 36 Yellow w/ Brown Stripe
37 Black 38 Red
39 Blue 40 Orange
41 Yellow 42 Brown
43 Red w/ Black Stripe 44 Blue w/ Black Stripe
45 Orange w/ Black Stripe 46 Yellow w/ Black Stripe
47 Brown w/ Black Stripe 48 Black w/ Red Stripe
49 Blue w/ Red Stripe 50 Orange w/ Red Stripe
Jacket: - Black sunlight resistant, flame retardant polyvinyl chloride per UL 1277 requirements for Type TC power and control cables
Applications:
- Control circuits for operation and interconnection of protective and signaling devices, and for general use in manufacturing, industrial and commercial distribution systems
- UL listed and labeled for installation in ladders, troughs, channels, solid bottom trays and other similar structures (NEC Articles 318 and 340), and in duct, conduit, and wireways
- In hazardous locations per NEC Articles 500 and 501. May be used in wet or dry locations, sunlight resistant, and suitable for direct burial
Standards:
- UL Type TC, 600 Volt
- NEC Type TFN Conductors
- IEEE 1202 (70,000 BTU/hr) / CSA FT4
- IEEE 383 (70,000 BTU/hr)
- UL Subject 1277 (70,000 BTU/hr)
- OSHA Acceptable
Part # AWG Size No. of Cond. Nom. Jacket Thick. Nom. O.D. Lbs./M’ Recommended Fitting
1A11602F* 16 2 .045” .200” x .310” 48 -
1A11602R* 16 2 .045” .300” 50 TCF07540A
1A11603 16 3 .045” .315” 60 TCF07540A
1A11604 16 4 .045” .340” 74 TCF07540A
1A11605 16 5 .045” .370” 97 TCF07540A
1A11606 16 6 .045” .390” 100 TCF07540A
1A11607 16 7 .045” .400” 111 TCF07540A
1A11609 16 9 .045” .460” 141 TCF05054A
1A11610 16 10 .045” .500” 154 TCF05054A
1A11612 16 12 .045” .515” 178 TCF05054A
1A11615 16 15 .060” .605” 239 TCF05067A
1A11616 16 16 .060” .594” 248 TCF07567A
1A11619 16 19 .060” .635” 284 TCF07567A
1A11620 16 20 .060” .700” 297 TCF07578A
1A11625 16 25 .060” .735” 364 TCF07578A
1A11630 16 30 .060” .775” 426 TCF07578A
1A11637 16 37 .080” .880” 548 TCF10088A
1A11650 16 50 .080” 1.03” 730 TCF100109A
Note: The data shown are approximate and subject to standard industry and manufacturer tolerances.
*ER Rating only applies to 3 conductors or more